The PRI/QSIG Network Specific Facilities form is used to define network specific facilities on a Fixed or Call-by-Call basis. Use this form when performing the following tasks:
PRI/QSIG Network Specific Facilities applies to T1 only.
Name |
Description |
Default Value |
Controller Module |
System-generated, protected field. Identifies the module position (1-4) in the controller. |
|
Port |
System-generated, protected field. Identifies the port (1 or 2) in the module. |
|
Link Number |
System-generated, protected field. |
|
Protocol |
System-generated, protected field. From the ISDN Protocol form. |
|
Protocol Variant |
System-generated, protected field. From the ISDN Protocol form. |
|
Type |
Fixed or Call by Call. |
Fixed |
Fixed Network Specific Facilities |
Global default depending on the protocol and variant. Refer to the dependencies table. |
Unassigned |
Call by Call Network Specific Facilities |
Depending on the protocol and variant. Refer to the dependencies table. |
Unassigned |
Parameter Length |
Applicable to NI-2 protocol and some values from
call by call (1-5 digits). Parameter Length is displayed for the following
variant and call-by-call value: |
System-dependent |