None
Obtains a list of PCM fault totals.
This command lists the assigned PCM links and indicates for each the number of isolated or unisolated faults.
The first part of the report (Circuit Switch Matrix) shows all the links available. The second part shows the links allocated to each card.
On the SUPERCONSOLE 1000, this command is found under the DIAGNOSTICS group of commands.
PCM Totals Command Printout Headings (see Example) |
|
Heading |
Description |
Main Controller PLANE: |
Identifies the plane (A) in use and status (Active) when the command was entered. |
Cab |
Refers to the cabinet in which the link node exists. |
Shelf |
Refers to the shelf in which the link node exists. |
Slot |
Refers to the card slot in which the link node exists. |
Description |
Card type to which specified PCM links are connected such as: Circuit Switch Matrix Peripheral Controller Conference DSU DS1 Formatter or CEPT Formatter Note: Only installed cards with assigned PCM links are shown. |
Faults Isolated |
Number of known faults that have been isolated down to the particular card. |
Faults Unisolated |
Number of faults discovered while testing PCM links (faults not isolated down to this particular card). Unisolated faults will be shown for each end of link. |
Link Ranges |
Range of links currently assigned to the specified card. |
System Response:
*** PCM FAULT TOTALS *** Main Controller PLANE: A Active Shelf | Description | Faults | Link Ranges Cab Slot| | Isolated Unisolated | --------------------------------------------------------------------- 1 1 1 |MN3300 Controll | 0 0 | 0-242 --------------------------------------------------------------------- 1 3 32 |IP Controller | 0 0 |128-242 6 1 16 |Peripheral Cont I | 0 0 | 20- 23 8 1 16 |Peripheral Cont I | 0 0 | 32- 35 1 1 1 |MN3300 Controll | 0 0 |128-242 1 1 1 |MN3300 Controll | 0 0 |128-242 1 1 10 |Communication Proc | 0 0 | 51- 51 1 1 13 |Communication Proc | 0 0 | 78- 78 7 1 2 |Universal T1 | 0 0 | 26- 27 7 1 3 |Universal E1 | 0 0 | 24- 25 7 1 4 |DS1 Formatter | 0 0 | 28- 29 9 1 2 |Universal T1 | 0 0 | 36- 36 9 1 3 |Universal T1 | 0 0 | 37- 37 1 1 1 |MN3300 Controll | 0 0 | 0- 0 2- 9 --------------------------------------------------------------------- |