SYSTEM TOTALS (SY T)

Qualifiers:

None

Purpose:

Displays the total number of programmed trunks, lines, stations, and attendants (with a breakdown by device type).

Details:

The information provided by this command is used by PTT for charging purposes and, as such, accurately reflects the number of programmed extensions and trunks currently being used by the system.

Any station or trunk that has been assigned an extension number or a trunk number in their respective programming forms will be considered programmed.

The circuits included in the totals will not necessarily be in a working state.  The totals will include circuits in manbusy, under test, or in an indeterminate state.

Device types with zero programmed circuits (i.e. the database has none of these devices programmed) will not be included in the breakdown of the totals.

On the SUPERCONSOLE 1000, this command is found under the REPORTS group of commands.

Example:

Entry: SY T

System Response:  

TOTAL TRUNKS

116

TOTAL STATIONS

623

TOTAL ATTENDANTS

1

 

 

 

 

 

 

E&M Trunks

1

UNIVERSAL T1 Trunks

115

 

 

 

 

On Premise Stations

67

Off Premise Stations

3

DNI Stations

536

8 Port On Premise Station

17