CO Tone Detection

Purpose:

The CO Tone Detection form allows you to enable or disable Tone Detection for Central Office trunks. You can also change the parameters for tone detection.

Use this form to perform the following tasks:

Field Descriptions

Parameter

Description

Default Value

CO Tone Detection Enabled

Select the check box to enable the CO Tone Detection feature. Clear the check box to disable the feature.

Disabled/false

Country

A read-only field that indicates the country variant of the system.

 

Sample Time (s)

Enter the time in seconds. This value is the length of time required by the 3300 ICP to analyze the CO tone on the line. The range is from 1 to 10 seconds.

Blank

Delay Time (s)

Enter the delay time in seconds. This value is the length of time a line must be off hook before the 3300 ICP begins CO tone detection. The range is from 1 to 30 seconds.

Blank

Sensitivity (dB)

Enter the Sensitivity in decibels (dB). This value is the tone level threshold for the tone detector. It must be a negative value. The range is from -40 to 0.

Blank

Tone Type

Select continuous tone or select non-continuous tone.

Blank

Frequency 1 (Hz)

Enter the number in Hertz for Frequency 1. The range is from 0 to 4KHz.

Blank

Frequency 2 (Hz)

Enter the number in Hertz for Frequency 2. The range is from 0 to 4KHz.

Blank

On 1 (ms)

Enter the ON 1 cadence in milliseconds. This value is the duration of the first tone burst (the ON time). The range is from 0 to 10,000 milliseconds.

  • Note: ON_1, OFF_1, ON_2, and OFF_2 are the basic ON and OFF bursts (in milliseconds) that may repeat, in that order, to constitute the tone's cadence.

Blank

Off 1 (ms)

Enter the OFF 1 cadence in milliseconds. This value is the time between the first and second tone burst (the OFF time). The range is from 0 to 10,000 milliseconds.

Blank

On 2 (ms)

Enter the ON 2 cadence in milliseconds. This value is the duration of the second tone burst (the ON time). The range is from 0 to 10,000 milliseconds.

Blank

Off 2 (ms)

Enter the OFF 2 cadence in milliseconds. This value is the time between the second tone burst and the next tone burst (the OFF time). The range is from 0 to 10,000 milliseconds.

Blank