Dimension Parameter Defaults

The Dimension Parameters and defaults are displayed in the Dimension Selection form. Refer to Change Resource Dimensions for programming instructions.

The following tables list the Dimension Parameters and defaults for the

Dimension Parameters for CX, CXi, MX, and LX Systems

Parameter Name and Range of Values

Unit Size (bytes)

Default # of Units

Attendant Consoles (2-48)

112

24

Attendant Groups (2-100)

208

48

Broadcast Groups (12-16000)

245

1875

Call History (2-65000)

42

14000

Call Reroute Always (10-250)

8

175

Call Reroute 1st Alt (10-500)

6

336

Call Reroute 2nd Alt (10-100)

6

32

Class of Service (10-96)

94

96

Default Account Codes (10-600)

8

225

Departments (10-5000)

12

2000

Digit Blocks (21556 max.)

78

4056

1200 (See Note 1)

DNI Channels (36-16000)

4

3319

DTMF Receivers (16-200)

6

128

DTS Service (10-300)

30

64

Hunt Groups (10-255)

317

176

Independent Account Codes (10-11000)

12

11000

Locations (10-5000)

10

2000

Multiline Sets (12-6000)

269

756

Multiline Sets Button Dig (32766 max.)

6 / bucket

9001

Personal Speed Call Users (10-1000)

24 / block The personal speed call users resource is measured in blocks. The Unit Size gives the number of bytes required to add one block. Adding one block adds 10 speedcall numbers for one user. A block cannot be split among different users.

500

Pickup Groups (10-800)

316

200

Route Lists (10-1200)

36

128
600 (see Note 1)

Route Plans (10-100)

50

32

Routes (10-2400)

18

200

1200 (see Note 1)

Single Line Sets (16-5000)

144

700

Speed Call Digit String (32766 max.)

6 / bucket

2501

3026/6701 (see Note 4)

System Account Codes (10-100)

8

24

System Digit Strings (65000 max.)

6 / bucket

30001
50001 (See Note 1)

105000 (See Note 2)

System Speed Call (10-3000)

12

1000

2000 (see Note 1)

Telephone Directory (55-65000)

42

20000

50005 (see Note 1)

105000 (See Note 2)

Transient Digit String (32766 max.)

6 / bucket

6601

Trunk Groups (8-250)

372

112

Trunks (8-2000)

26

628

Trunk Service (8-500)

30

150

PKM Devices (2-500)

492

75

SUPERSET Callback Messages (48-10000)

52

500

Busy Lamp Groups (2-5000)

196

439

Page Groups (2-100)

1006

16

Suites (2-2332)

116

364

Linked Suites (2-777)

80

500

  • Note 1: Default value when 250 or 999 Maximum Elements Per Cluster is selected.

  • Note 2: Default value when 999 Maximum Elements Per Cluster is selected.

Dimension Parameters for MXe, MXe Server and LX Systems, with at least 512 MB of Memory

Parameter Name and Range of Values

Unit Size (bytes)

Default # of Units

Attendant Consoles (2-48)

112

24

Attendant Groups (2-100)

208

48

Broadcast Groups (12-16000)

245

9000

Call History (2-65000)

42

56000

Call Reroute Always (10-250)

8

175

Call Reroute 1st Alt (10-500)

6

336

Call Reroute 2nd Alt (10-100)

6

32

Class of Service (10-96)

94

96

Default Account Codes (10-600)

8

225

Departments (10-5000)

12

2000

Digit Blocks (21556 max.)

78

12056
12256 (see Note 2)

20001 (see Note 3)

DNI Channels (36-16000)

4

13068

DTMF Receivers (16-200)

6

128

DTS Service (10-300)

30

64

Hunt Groups (10-255)

317

176

Independent Account Codes (10-15000)

12

11000

Locations (10-5000)

10

2000

Multiline Sets (12-6000)

269

5665

Multiline Sets Button Dig (65000 max.)

12 / bucket

28000

Personal Speed Call Users (10-1000)

24 / block The personal speed call users resource is measured in blocks. The Unit Size gives the number of bytes required to add one block. Adding one block adds 10 speedcall numbers for one user. A block cannot be split among different users.

500

Pickup Groups (10-800)

316

200

Route Lists (10-1200)

36

128
600 (see Note 1)

Route Plans (10-100)

50

32

Routes (10-2400)

18

200

1200 (see Note 1)

Single Line Sets (16-5000)

144

700

Speed Call Digit String (32766 max.)

12 / bucket

2501

3026/6701 (see Note 4)

System Account Codes (10-100)

8

24

System Digit Strings (130,000 max.)

6 / bucket

30001
56000 (see Note 1)

105000 (see Note 3)

System Speed Call (10-3000)

12

1000

2000 (see Note 1)

Telephone Directory (55-65000)

42

20000

50005 (see Note 1)

65000 (see Note 3)

Transient Digit String (32766 max.)

12 / bucket

13430

Trunk Groups (8-250)

372

112

Trunks (8-2000)

26

628

Trunk Service (8-500)

30

150

PKM Devices (2-500)

492

75

SUPERSET Callback Messages (48-10000)

52

3999

Busy Lamp Groups (2-5000)

196

439

Page Groups (2-100)

1006

16

Suites (2-2332)

116

364

Linked Suites (2-777)

80

500

  • Note 1: Default value when 250 Maximum Elements Per Cluster is selected.

  • Note 2: 12256 is the default value on systems with 5600 configurable IP devices.

  • Note 3: Default value when 999 Maximum Elements Per Cluster is selected.

  • Note 4: 3026 and 6701 are the defaults for 700- and 5600-user systems respectively.