Loudspeaker Paging

Purpose:

The Loudspeaker Paging form is used to assign zone numbers and interconnect numbers to loudspeaker paging circuits.

Use this form when performing the following tasks:

Field Descriptions

Parameter

Description

Default Value

Cabinet, Shelf, Slot, Circuit

System-generated, protected field. Indicates the physical location ID (PLID) of the paging circuits.

 

Card Type

System-generated, protected fields indicates the card type associated with the PLID. ASU E&M trunks are used for loudspeaker paging.

 

Zone Number

Enter the zone number to which the paging circuit is assigned. The system supports 15 individual paging zones plus the "ALL" paging zone. The zone number must be unique. A zone cannot be assigned to more than one paging circuit. On a multiple-zone system, all-zone paging must be designated as "00", regardless of whether all-zone paging is enabled. This means that you must assign a zone number of "0" to the "ALL" paging zone.

Blank

Interconnect Number

Enter a valid interconnect number that indexes into Interconnect Restriction where the interconnect rights for the paging circuit are defined.

Blank