The Controller Module Configuration form identifies the modules that are in the controller.
Use this form to perform the following tasks:
Parameter |
Description |
Default Value |
Module |
System-generated, protected field. Indicates the module position in the controller. |
|
Programmed Module Type |
For MX, MXe, and LX controllers, select "Dual FIM", "Dual Framer", "T1/E1", "Quad BRI", or "Quad CIM" to match the Installed Module Type. For the CX, CXi, CX II, or CXi II controller, you can select "T1/E1", "Quad BRI", or "Quad CIM". For the AX controller, you can select "Dual Framer", "T1/E1", "Quad BRI", or "Quad CIM". You can install a maximum of two Quad CIM modules in a 3300 ICP controller with the exception of the AX controller which only supports one Quad CIM module. A Quad CIM module provides 4 ports. You can connect an ASU, a Universal ASU, or an ASU II to a Quad CIM port.
|
No Module Programmed |
Installed Module Type |
System-generated, protected field. Indicates the type of module installed in the specified location. |
|