Program BRI Trunks

Before You Begin

Ensure that:

Programming

To program BRI trunks:

  1. Digital Link Descriptors form
    Enter "A" or "B" in the Address for Message Control field.
    Enter "DPNSS" in the Integrated Digital Access field.

  2. Digital Links form
    Complete the Digital Link Descriptor Number field.

  3. Class of Service Options form
    Set the ANI/DNIS ISDN Number Delivery Trunk field to "Yes".

  4. MSDN-DPNSS-DASS II Trunk Circuit Descriptors form
    Enter "MSDN-DPNSS" in the Signaling Protocol field, "CEPT" in the Card Type field, "Incoming" or "Outgoing" (depending upon your system) in the Dual Seizure Priority field, "LT" for NA, or either "LT" or "NT" for EMEAAP in the BRI Mode field, and "Local Office" in the Far End Connection field.

  5. Trunk Attributes form
    Complete the COS number.
    Set the Dial in Trunks: Incoming Digit Modification field to "absorb".

  6. Digital Trunks form
    Complete the Trunk Number, Trunk Service Number, Circuit Descriptor, and Interconnect Number fields.

  7. Network Synchronization form (optional)
    Assign a source connection to a Network Source Clock.

The system programming is now complete. The BRI NSU must now be programmed.

  1. Connect a computer to the RS-232 port on the BRI NSU.

  2. Log on to the BRI NSU.

  3. Configure Usernames and Passwords.

  4. Follow the Quick Setup instructions as required.

  5. Complete specific programming for BRI.

  6. Log off after all programming is complete.

  7. Detach the computer from the port.